Pump Skids Configured to Your Specification.
We are not a pump brand. We choose the pump, the drive and the panel that fit the duty and supply them as one package, with one point of responsibility.
Independent by Design.
A packaged skid puts pumps, drives, panel, headers and valves on one base, piped and wired. On site it needs two pipe connections and one power supply.
Because we do not make pumps, we are free to pick the right one. If the consultant has named a basis of design, we supply to it. If not, we propose one and show the data.
Every skid arrives with its test records, wiring diagrams and general-arrangement drawing.
Packaged skid ready for delivery Why Specify It
One package, one point of responsibility, one set of documents.
Point of responsibility
One supplier owns hydraulics, electrics, controls and the base. There is no gap between pump vendor, panel builder and installer.
Configured, not catalogued
Duty, standby arrangement, control philosophy and footprint are set from your schedule rather than a fixed model list.
Component choice
Pumps, VFDs and control components are selected from established manufacturers to suit the specification; brand is a decision, not a constraint.
Tested before delivery
Hydrostatic test on the pipework and a functional run test of pumps and controls, recorded and issued with the unit.
Site connections
Two flanged pipe connections and one incoming supply. Positioning, levelling and connection are the only site tasks.
Documentation that travels
General arrangement, P&ID, wiring diagrams, test certificates and O&M manual issued with every skid.
Sized for the plant room
Compact headers, maintenance clearances and lifting points specified around the room you have, including split skids for restricted access.
Energy-aware control
VFD constant-pressure control, staged duty and sleep modes reduce running cost and pressure surges.
Standby and redundancy
Duty/standby and duty/assist/standby arrangements with automatic changeover for critical buildings.
Package Types
Three standard arrangements cover most buildings. Each one is sized for the job, not picked from a list.
Water transfer sets
Ground-tank to roof-tank transfer, level-controlled, with dry-run protection.
| Arrangement | Simplex or duplex, automatic changeover |
|---|---|
| Pumps | End-suction or vertical multistage |
| Control | Float or level-transmitter, DOL or soft start |
| Typical use | Villas, low- and mid-rise buildings |
Pressure booster sets
Constant-pressure supply to upper floors with variable-speed control and a pressure vessel.
| Arrangement | Duplex, triplex or quad |
|---|---|
| Pumps | Vertical multistage |
| Control | VFD constant pressure, cascade, sleep mode |
| Typical use | Towers, hotels, hospitals, retail |
Sewage and sump lift stations
Duplex submersible pumps on guide rails with a float- or level-controlled panel.
| Arrangement | Duty/standby, alternating |
|---|---|
| Pumps | Submersible sewage or drainage |
| Control | Level control, high-level alarm, BMS output |
| Typical use | Basements, villas, industrial sites |
What we integrate
Components selected to suit the duty and the specification.
| Drives | Variable-frequency drives, soft starters |
|---|---|
| Panels | IEC 61439 panels, IP54 or better |
| Pipework | Galvanised or stainless headers, isolation and non-return valves |
| Instruments | Pressure transmitters, gauges, level sensors, flow switches |
Where It Is Specified
The same three packages, sized and controlled for the building.
Commercial towers
Booster sets with zoned pressure and duty/assist/standby for 24-hour buildings.
Villas and residential
Compact transfer or booster sets sized for domestic demand and quiet operation.
Hospitality
Reliable hot- and cold-water pressure with redundancy and BMS reporting.
Healthcare
Redundant pumping, alarms to the BMS and full documentation for authority approval.
Industrial facilities
Process water transfer, effluent and sump lift with heavy-duty submersibles.
Retail and mixed-use
Boosters serving multiple tenancies with flow-matched staging.
From Specification to Delivery
Four steps from specification to a skid on site.
-
Select
Duty, head and control philosophy are taken from the schedule; pumps, drives and panel components are selected to suit.
- Hydraulic selection
- Panel schedule
- General-arrangement drawing
-
Configure
Base, headers, valves, instruments and the control panel are specified around the selected pumps and the space available.
- Header and valve layout
- Panel and VFD schedule
- Lifting and access
-
Package
The skid is assembled, piped and wired as one unit, with the hydrostatic and functional tests recorded.
- Hydrostatic 1.5× working pressure
- Run and control sequence test
- Documentation pack
-
Deliver and support
Delivered to site with drawings and documentation. We support the contractor's commissioning and start-up.
- General arrangement and P&ID
- Wiring diagrams
- Start-up support
Performance Data
Typical envelope for building packages. Larger duties on request.
| Parameter | Value | Basis |
|---|---|---|
| Flow range | Up to 200 m³/h per package | Typical building envelope |
| Head range | Up to 160 m | Typical building envelope |
| Pump count | 1 to 4 per skid | Configuration |
| Control | VFD constant pressure, DOL, soft start | Per specification |
| Panel standard | IEC 61439, IP54 enclosure | Standard |
| Hydrostatic test | 1.5 × maximum working pressure | Factory test |
| Header material | Galvanised steel or stainless steel 304/316 | Per specification |
| Base frame | Welded structural steel, powder-coated | Standard |
| BMS interface | Volt-free contacts; Modbus or BACnet on request | Option |
Datasheets and Documents
Sent from our engineering office on request.
Common Questions
Do you make your own pumps?
Can you supply to a consultant's named basis of design?
What do you need to quote?
What is tested before delivery?
Can the skid be split for access?
Do you commission on site?
Other Solutions
Often specified together on the same project.
Glass-wool pre-insulated duct systems
CLIMAVER glass-wool duct sections, insulated and airtight as made, supplied to your schedule.
View SolutionRefrigeration equipment and condensing units
Condensing units, evaporators and racks, matched from the load, the temperature and the ambient.
View SolutionEnquire About Packaged Pump Skids
Drawings or a schedule are enough for a quotation.
- info@technicsfzc.com
- Phone
- +971 6 526 9175
- Fax
- +971 6 526 9178
- Hours
- 8 AM to 6 PM, Saturday to Thursday
- Address
- Technics Middle East FZC, Block 1H, Plot 09 & 10B, Hamriyah Free Zone, Phase 1, P.O. Box 49407, Sharjah, United Arab Emirates